Logo Logo

Citation: Heck, Katrin and Litzenburger, Friederike and Kunzelmann, Karl-Heinz: In-vitro caries diagnostic study - 375 bitewing radiographs of extracted human teeth. 2. January 2024. Open Data LMU. 10.5282/ubm/data.444

In-vitro caries diagnostic study - 375 bitewing radiographs of extracted human teeth
In-vitro caries diagnostic study - 375 bitewing radiographs of extracted human teeth

The aim of the research project was to test the validity and reliability of new methods of caries diagnostics on extracted human molars in vitro. A total of 375 teeth were examined. Microtomographic images were taken as a reference standard. Radiographs of these teeth and white light images from the occlusal, proximal, buccal and oral directions were taken as a comparative imaging technique to the new methods. As new examination methods, tranisillumination images were taken from the occlusal direction using near-infrared light with wavelengths of 1050, 1200 and 1300 nm with two different indium gallium arsenide (InGaAs) cameras. On the other hand, reflection images of the occlusal, buccal and oral areas were taken using near-infrared light with wavelengths of 1050, 1200, 1300 and 1550 nm, also with two InGaAs cameras. The cameras differed in the size of their sensor, with 320x256 and 640x512 pixels respectively. This is the bitewing X-ray data set of the 375 teeth.

Other data publications from the "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.441 (near-infrared transillumination images at 1050, 1200 and 1300 nm from occlusal of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

,

Im Rahmen des Forschungsprojektes sollten an extrahierten menschlichen Molaren in-vitro neue Methoden der Kariesdiagnostik auf ihre Validität sowie Reliabilität überprüft werden. Insgesamt wurden 375 Zähne untersucht. Als Referenzstandard wurden microtomographische Aufnahmen angefertigt. Als vergleichende Aufnahmetechnik zu den neuen Methoden wurden Röntgenaufnahmen dieser Zähne angefertigt sowie Weisslichtbilder aus okklusaler, approximaler, bukkaler und oraler Richtung. Als neue Untesuchungsmethoden wurden zum einen Tranisilluminationsaufnahmen von okklusal mittels nahinfrarotem Licht der Wellenlängen 1050, 1200 und 1300 nm mit zwei unterschiedlichen Indium-Gallium-Arsenid (InGaAs) Kameras aufgenommen. Zum anderen Reflektionsaufnahmen mittels nahinfrarotem Licht der Wellenlängen 1050, 1200, 1300 und 1550 nm, ebenfalls mit zwei InGaAs Kameras, von okklusal, bukkal sowie oral. Die Kameras unterschieden sich in der Größe ihres Sensors, mit 320x256 bzw. 640x512 Pixel. Hier vorliegend der Bissflügelröntgen-Datensatz der 375 Zähne.

Verwandte Datensätze von: "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.441 (near-infrared transillumination images at 1050, 1200 and 1300 nm from occlusal of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Bissflügelröntgen, Zähne, Kariesdiagnostik
Heck, Katrin
Litzenburger, Friederike
Kunzelmann, Karl-Heinz
2024

[thumbnail of Radiography] Other (Radiography)
radiography.zip

155MB
[thumbnail of DataCite XML] Other (DataCite XML)
metadata.xml

5kB
[thumbnail of Readme] Plain Text (Readme)
README.txt

5kB

DOI: 10.5282/ubm/data.444

This dataset is available unter the terms of the following Creative Commons LicenseCC BY-NC-SA 4.0

Abstract

The aim of the research project was to test the validity and reliability of new methods of caries diagnostics on extracted human molars in vitro. A total of 375 teeth were examined. Microtomographic images were taken as a reference standard. Radiographs of these teeth and white light images from the occlusal, proximal, buccal and oral directions were taken as a comparative imaging technique to the new methods. As new examination methods, tranisillumination images were taken from the occlusal direction using near-infrared light with wavelengths of 1050, 1200 and 1300 nm with two different indium gallium arsenide (InGaAs) cameras. On the other hand, reflection images of the occlusal, buccal and oral areas were taken using near-infrared light with wavelengths of 1050, 1200, 1300 and 1550 nm, also with two InGaAs cameras. The cameras differed in the size of their sensor, with 320x256 and 640x512 pixels respectively. This is the bitewing X-ray data set of the 375 teeth. Other data publications from the "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.441 (near-infrared transillumination images at 1050, 1200 and 1300 nm from occlusal of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Abstract

Im Rahmen des Forschungsprojektes sollten an extrahierten menschlichen Molaren in-vitro neue Methoden der Kariesdiagnostik auf ihre Validität sowie Reliabilität überprüft werden. Insgesamt wurden 375 Zähne untersucht. Als Referenzstandard wurden microtomographische Aufnahmen angefertigt. Als vergleichende Aufnahmetechnik zu den neuen Methoden wurden Röntgenaufnahmen dieser Zähne angefertigt sowie Weisslichtbilder aus okklusaler, approximaler, bukkaler und oraler Richtung. Als neue Untesuchungsmethoden wurden zum einen Tranisilluminationsaufnahmen von okklusal mittels nahinfrarotem Licht der Wellenlängen 1050, 1200 und 1300 nm mit zwei unterschiedlichen Indium-Gallium-Arsenid (InGaAs) Kameras aufgenommen. Zum anderen Reflektionsaufnahmen mittels nahinfrarotem Licht der Wellenlängen 1050, 1200, 1300 und 1550 nm, ebenfalls mit zwei InGaAs Kameras, von okklusal, bukkal sowie oral. Die Kameras unterschieden sich in der Größe ihres Sensors, mit 320x256 bzw. 640x512 Pixel. Hier vorliegend der Bissflügelröntgen-Datensatz der 375 Zähne. Verwandte Datensätze von: "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.441 (near-infrared transillumination images at 1050, 1200 and 1300 nm from occlusal of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Uncontrolled Keywords

Bissflügelröntgen, Zähne, Kariesdiagnostik

Item Type:Data
Contact Person:Heck, Katrin
E-Mail of Contact:Katrin.Heck at med.uni-muenchen.de
Subjects:Medicine
Dewey Decimal Classification:600 Technology, Medicine
600 Technology, Medicine > 610 Medical sciences and medicine
ID Code:444
Deposited By: FDM-Beratung UB der LMU München
Deposited On:05. Mar 2024 15:19
Last Modified:05. Mar 2024 15:37

Repository Staff Only: item control page