The aim of the research project was to test the validity and reliability of new methods of caries diagnostics on extracted human molars in vitro. A total of 375 teeth were examined. Microtomographic images were taken as a reference standard. Radiographs of these teeth and white light images from the occlusal, proximal, buccal and oral directions were taken as a comparative imaging technique to the new methods. As new examination methods, tranisillumination images were taken from the occlusal direction using near-infrared light with wavelengths of 1050, 1200 and 1300 nm with two different indium gallium arsenide (InGaAs) cameras. On the other hand, reflection images of the occlusal, buccal and oral areas were taken using near-infrared light with wavelengths of 1050, 1200, 1300 and 1550 nm, also with two InGaAs cameras. The cameras differed in the size of their sensor, with 320x256 and 640x512 pixels respectively. This is the near-infrared transillumination image data set of the 375 teeth.

Other data publications from the "In-vitro caries diagnostic study":

https://doi.org/10.5282/ubm/data.444 (375 bitewing radiographs of extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

,

Im Rahmen des Forschungsprojektes sollten an extrahierten menschlichen Molaren in-vitro neue Methoden der Kariesdiagnostik auf ihre Validität sowie Reliabilität überprüft werden. Insgesamt wurden 375 Zähne untersucht. Als Referenzstandard wurden microtomographische Aufnahmen angefertigt. Als vergleichende Aufnahmetechnik zu den neuen Methoden wurden Röntgenaufnahmen dieser Zähne angefertigt sowie Weisslichtbilder aus okklusaler, approximaler, bukkaler und oraler Richtung. Als neue Untesuchungsmethoden wurden zum einen Tranisilluminationsaufnahmen von okklusal mittels nahinfrarotem Licht der Wellenlängen 1050, 1200 und 1300 nm mit zwei unterschiedlichen Indium-Gallium-Arsenid (InGaAs) Kameras aufgenommen. Zum anderen Reflektionsaufnahmen mittels nahinfrarotem Licht der Wellenlängen 1050, 1200, 1300 und 1550 nm, ebenfalls mit zwei InGaAs Kameras, von okklusal, bukkal sowie oral. Die Kameras unterschieden sich in der Größe ihres Sensors, mit 320x256 bzw. 640x512 Pixel. Hier vorliegend der Nahinfrarot-Transilluminationsbilder-Datensatz der 375 Zähne.

Verwandte Datensätze von: "In-vitro caries diagnostic study":

https://doi.org/10.5282/ubm/data.444 (375 bitewing radiographs of extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Not available
Heck, Katrin
Litzenburger, Friederike
Karl-Heinz, Kunzelmann
2024

[thumbnail of Near Infrared Transillumination (zip)] Other (Near Infrared Transillumination (zip))
near-infrared transillumination.zip - Veröffentlichte Version

60MB
[thumbnail of Metadata (DataCite XML)] Other (Metadata (DataCite XML))
metadata.xml - Veröffentlichte Version

5kB
[thumbnail of Readme] Plain Text (Readme)
README.txt

5kB

DOI: 10.5282/ubm/data.441

Dieser Datensatz steht unter der Creative Commons Lizenz
CC BY-NC-SA 4.0

Be­schrei­bung

The aim of the research project was to test the validity and reliability of new methods of caries diagnostics on extracted human molars in vitro. A total of 375 teeth were examined. Microtomographic images were taken as a reference standard. Radiographs of these teeth and white light images from the occlusal, proximal, buccal and oral directions were taken as a comparative imaging technique to the new methods. As new examination methods, tranisillumination images were taken from the occlusal direction using near-infrared light with wavelengths of 1050, 1200 and 1300 nm with two different indium gallium arsenide (InGaAs) cameras. On the other hand, reflection images of the occlusal, buccal and oral areas were taken using near-infrared light with wavelengths of 1050, 1200, 1300 and 1550 nm, also with two InGaAs cameras. The cameras differed in the size of their sensor, with 320x256 and 640x512 pixels respectively. This is the near-infrared transillumination image data set of the 375 teeth. Other data publications from the "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.444 (375 bitewing radiographs of extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Be­schrei­bung

Im Rahmen des Forschungsprojektes sollten an extrahierten menschlichen Molaren in-vitro neue Methoden der Kariesdiagnostik auf ihre Validität sowie Reliabilität überprüft werden. Insgesamt wurden 375 Zähne untersucht. Als Referenzstandard wurden microtomographische Aufnahmen angefertigt. Als vergleichende Aufnahmetechnik zu den neuen Methoden wurden Röntgenaufnahmen dieser Zähne angefertigt sowie Weisslichtbilder aus okklusaler, approximaler, bukkaler und oraler Richtung. Als neue Untesuchungsmethoden wurden zum einen Tranisilluminationsaufnahmen von okklusal mittels nahinfrarotem Licht der Wellenlängen 1050, 1200 und 1300 nm mit zwei unterschiedlichen Indium-Gallium-Arsenid (InGaAs) Kameras aufgenommen. Zum anderen Reflektionsaufnahmen mittels nahinfrarotem Licht der Wellenlängen 1050, 1200, 1300 und 1550 nm, ebenfalls mit zwei InGaAs Kameras, von okklusal, bukkal sowie oral. Die Kameras unterschieden sich in der Größe ihres Sensors, mit 320x256 bzw. 640x512 Pixel. Hier vorliegend der Nahinfrarot-Transilluminationsbilder-Datensatz der 375 Zähne. Verwandte Datensätze von: "In-vitro caries diagnostic study": https://doi.org/10.5282/ubm/data.444 (375 bitewing radiographs of extracted human teeth) https://doi.org/10.5282/ubm/data.445 (375 microtomographic images of the coronal part of extracted human teeth) https://doi.org/10.5282/ubm/data.446 (white light images from occlusal, proximal, buccal and oral direction of 375 extracted human teeth) https://doi.org/10.5282/ubm/data.447 (near-infrared reflection images at 1050, 1200, 1300 and 1550 nm from occlusal, buccal and oral direction of 375 extracted human teeth)

Quelle

nahinfrarote Transillumination, Zähne, Kariesdiagnostik

Dokumententyp:Daten
Name der Kontakt­person:Heck, Katrin
E-Mail der Kontaktperson:Katrin.Heck at med.uni-muenchen.de
Fächer:Medizin
Dewey Dezimal­klassi­fikation:600 Technik, Medizin, angewandte Wissenschaften
600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin und Gesundheit
ID Code:441
Eingestellt von: FDM-Beratung UB der LMU München
Eingestellt am:05. Mrz. 2024 15:19
Letzte Änderungen:05. Mrz. 2024 15:39

Nur für Administratoren und Editoren: Dokument bearbeiten