Logo Logo

Zitation: Ludwig-Maximilians-Universität München, Ballhausen, Hendrik und Li, Minglun und Belka, Claus: Prostate intra-fraction motion data recorded by transperineal ultrasound (ProMotion LMU dataset, 2024 edition). 9. Januar 2024. Open Data LMU. 10.5282/ubm/data.428

Prostate intra-fraction motion data recorded by transperineal ultrasound (ProMotion LMU dataset, 2024 edition)
Prostate intra-fraction motion data recorded by transperineal ultrasound (ProMotion LMU dataset, 2024 edition)

Infra-fraction motion of the prostate was recorded during 3.423 fractions of image guided radiotherapy (IGRT) in 191 patients, 14 of which were treated by intensity modulated radiation therapy (IMRT), and 177 of which were treated by volumetric arc therapy (VMAT).

The prostate was imaged by three-dimensional and time-resolved transperineal ultrasound (4D-US) of type Clarity by Elekta, Stockholm, Sweden. The prostate volume was registered and the prostate position (center of volume) was recorded at a frequency of 2.0 samples per second. This raw data set contains a total of 1.985.392 prostate and patient couch positions over a time span of 272 hours, 52 minutes and 34 seconds of life radiotherapy as exported by the instrument software.

This data set has been used for the validation of models of prostate intra-fraction motion and for the estimation of the dosimetric impact of actual intra-fraction motion on treatment quality and side effects.

radiation therapy, prostate, ultrasound, intra-fraction motion, open data
Ballhausen, Hendrik
Li, Minglun
Belka, Claus
2024

Dies ist die aktuellste Version des Datensatzes.

[thumbnail of .csv raw data files as .zip archive] Text (.csv raw data files as .zip archive)
ProMotionLMU2024.zip

43MB
[thumbnail of .csv raw data files as .tar.gz archive] Text (.csv raw data files as .tar.gz archive)
ProMotionLMU2024.tar.gz

42MB

DOI: 10.5282/ubm/data.428

Dieser Datensatz steht unter der Creative Commons Lizenz
CC BY 4.0

Be­schrei­bung

Infra-fraction motion of the prostate was recorded during 3.423 fractions of image guided radiotherapy (IGRT) in 191 patients, 14 of which were treated by intensity modulated radiation therapy (IMRT), and 177 of which were treated by volumetric arc therapy (VMAT). The prostate was imaged by three-dimensional and time-resolved transperineal ultrasound (4D-US) of type Clarity by Elekta, Stockholm, Sweden. The prostate volume was registered and the prostate position (center of volume) was recorded at a frequency of 2.0 samples per second. This raw data set contains a total of 1.985.392 prostate and patient couch positions over a time span of 272 hours, 52 minutes and 34 seconds of life radiotherapy as exported by the instrument software. This data set has been used for the validation of models of prostate intra-fraction motion and for the estimation of the dosimetric impact of actual intra-fraction motion on treatment quality and side effects.

Keywords

radiation therapy, prostate, ultrasound, intra-fraction motion, open data

Dokumententyp:Daten
Name der Kontakt­person:Ballhausen, Hendrik
E-Mail der Kontaktperson:Hendrik.Ballhausen at med.lmu.de
Fakultät:Medizin
Dewey Dezimal­klassi­fikation:600 Technik, Medizin, angewandte Wissenschaften > 610 Medizin und Gesundheit
ID-Code:428
Hochgeladen von: PD Dr. Hendrik Ballhausen
Hochgeladen am:18. Jan. 2024 13:14
Letzte Änderungen:18. Jan. 2024 13:15

Verfügbare Versionen dieses Dokumentes

Nur für Mitarbeiter des Archivs: Bearbeiten